Measurments at different levels (at time of installation): 30 m: Net radiation, temperature, RH, wind speed, wind direction 15 m: temperature, wind speed, wind direction 7.5 m: temperature, RH, wind speed, wind direction 4 m: temperature, wind speed, wind direction, distance (3.5 m) 2 m: temperature (2.1), wind speed (2.4 m) 1 m : temperature (1.1 m), wind speed (1.3 m) Enclosure height (bottom of box): 2.5 m TIMESTAMP: YYYY-MM-DD HH:MM:SS RECORD: incremented number for record number PTemp: enclosure temperature (°C) batt_volt: volts T_air(1): 30 m temp (°C) T_air(2): 15 m temp (°C) T_air(3): 7.5 m temp (°C) T_air(4): 4 m temp (°C) T_air(5): 2 m temp (°C) T_air(6): 1 m temp (°C) Pressure: pressure in the enclosure (mb) wsCups(1): not installed wsCups(2): 1.3 m wind speed (m/s)* wsCups(3): 2.4 m wind speed (m/s)* wspd(1): 30 m wind speed (m/s) wspd(2): 15 m wind speed (m/s) wspd(3): 7.5 m wind speed (m/s) wspd(4): 4 m wind speed (m/s) wdir(1): 30 m wind direction (degrees) wdir(2): 15 m wind direction (degrees) wdir(3): 7.5 m wind direction (degrees) wdir(4): 4 m wind direction (degrees) Net_Shortwave: W/m2 Net_Longwave: W/m2 RH(1): 30 m RH (%) RH(2): 7.5 m RH (%) RawDist: Distance (m) – not temperature corrected SignalQuality: Quality of reading 0: not able to read distance 152-210: Good measurement quality numbers 210-300: Reduced echo signal strength 300-600: High measurement uncertainty Dist: temperature corrected distance (m) --------------- * The cup anemometer has an offset of 0.2 m/s